Aplicabil LISUN models: AB-EM

The AB-EM electromagnetic clamp complies with the national standard IEC 61000-4-6 and is a specialized product for testing the immunity of equipment to radio-frequency field-induced conducted disturbances.injecting disturbance signals into the cable assemblies in the slots so that the Equipment Under Test (EUT) is subjected to the levels specified in the national standard.

For precise measurements, the electromagnetic clamp is also equipped with an auxiliary absorption clamp and calibration pieces.

Categorii

See Tables 1 and 2 for the coupling coefficient and attenuation characteristic curves; the difference is 9.5 dB ± 1.5 dB.

Maximum input power: 100 W (5 minutes);

Injection frequency: 150 kHz to 230 MHz;

At frequencies greater than 10 MHz, the coupling/decoupling directivity is greater than 10 dB

Measurable cable diameter: <Φ18 mm

Atașamente

Instruction Manual 1 copy

Test Cable One

100W 6dB Attenuator One

Calibration Fixture (Optional) One set

Using Connection Diagrams

AB-EM

RF Conducted Immunity Test System-Figure1

AB-EM Data Sheet

Serial No.: 21021 Differential Error: 9.5 dB ± 1.5 dB Date: April 29, 2021

Frecventa (MHz) Coupling Coefficient (dB) Attenuation Coefficient (dB) Difference (dB)
0.15 -2.7 -12.3 9.6
0.2 -2.4 -12.0 9.6
0.3 -2.2 -11.8 9.6
0.32 -2.2 -11.8 9.6
0.35 -2.2 -11.8 9.6
0.4 -2.1 -11.8 9.7
0.45 -2.1 -11.8 9.7
0.5 -2.1 -11.8 9.7
0.55 -2.1 -11.8 9.7
0.6 -2.1 -11.8 9.7
0.65 -2.1 -11.8 9.7
0.74 -2.1 -11.8 9.7
0.75 -2.1 -11.8 9.7
0.8 -2.2 -11.9 9.7
0.85 -2.3 -11.9 9.6
0.9 -2.4 -12.1 9.7
0.95 -2.5 -12.1 9.6
1 -2.5 -12.1 9.6
1.5 -2.1 -11.7 9.6
2 -2.1 -11.7 9.6
2.5 -2.1 -11.7 9.6
3 -2.1 -11.7 9.6
4 -2.2 -11.8 9.6
5 -2.2 -11.8 9.6
6 -2.3 -11.8 9.5
7 -2.4 -11.8 9.4
8 -2.4 -11.8 9.4
9 -2.5 -11.9 9.4
10 -2.6 -11.9 9.3
12 -2.8 -12.1 9.3
15 -3.2 -12.4 9.2
18 -3.5 -12.6 9.1
20 -3.6 -12.8 9.2
22 -3.6 -12.8 9.2
25 -3.5 -12.8 9.3
28 -3.1 -12.4 9.3
30 -2.6 -11.9 9.3
32 -2.2 -11.5 9.3
35 -1.3 -10.6 9.3
38 -0.5 -9.8 9.3
40 0.0 -9.3 9.3
45 1.1 -8.4 9.5
50 1.8 -7.8 9.6
60 2.5 -7.4 9.9
70 2.6 -7.1 9.7
80 2.7 -6.9 9.6
85 2.9 -6.9 9.8
90 3.0 -6.9 9.9
95 3.2 -6.9 10.1
100 3.3 -6.8 10.1
120 3.5 -6.8 10.3
140 3.4 -7.0 10.4
160 2.6 -8.0 10.6
180 1.9 -8.2 10.1
200 0.9 -9.3 10.2
210 0.6 -9.6 10.2
220 0.1 -10.1 10.2
230 -0.1 -10.3 10.2

RF Conducted Immunity Test System-Figure2

RF Conducted Immunity Test System-Figure3

List of AB-EM Calibration Fixtures

Nu. Model Nume Quantity/piece
1 M-004 150Ω/50Ω Adapter 2
2 M-006 5 W / 50 Ω load 1
3 E-001 L-Shaped Calibration Bracket 2
4 E-003 4mm Test Rod (725mm) 1

*The 4mm test probe is inside the electromagnetic clamp packaging box;

Soluție de testare pentru corpuri de iluminat LED și drivere de putere LED

Sistem goniofotometric: LSG-6000, LSG-1890B, LSG-1700

Spectroradiometru și sistem de testare a sferei integratoare: LPCE-2 or LPCE-3

LED Life menține un sistem de testare în conformitate cu LM-80: LEDLM-80PL

Test de impermeabilitate pentru nivelurile IPX5 și IPX6: JL-56

Mașină de testare a etanșeității la praf pentru testarea IP5X și IP6X: SC-015

Testere de drivere de putere LED: LS2090 (pentru laborator) și ATE-2 (pentru linia de producție)

Tester de siguranță electrică: LS9955

Soluție de testare CFL și balast electronic

Sistem goniofotometric: LSG-1890B or LSG-1700

Integrarea sistemului de testare cu sferă și spectrofotometru: LPCE-2 or LPCE-3

Balast de referință reglabil: DYJ-50Hz, HCS-109A și DYJ-HID

Tester de balast electric: WT5000 (pentru laborator) și ATE-1 (pentru linia de producție)

Torsometru digital și tester de durată de viață multidirecțională: CH338 și CH316

Testere de siguranță electrică: LS9923, ZRS-3H, ZY-3

Soluții de testare EMC și EMI pentru corpuri de iluminat CFL și LED

Sistem de testare EMI: EMI-9KB or EMI-9KA

Simulator de descărcare electrostatică: ESD61000-2

Măsurarea imunității EFT: EFT61000-4

Generator de supratensiune: SG61000-5

Generator de căderi de tensiune și întreruperi: CSS61000-11

Generator de unde inelare: RWG61000-12

RF Conducted Immunity Test System-Figure4

www. Lisungroup.com